See the symptoms of How to fix water hammer problem in pipes. I checked all the wires and didn't find any problems, frayed insulation, etc. listeners: [], Continue with Recommended Cookies. Launch Product Selector. If the remote controller is not installed on the water heater, and there is a problem, the error codes will be shown differently. Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. This error code may appear when you power up the unit. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. If needed, adjust the thermostat setting. Solution: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. Now, press the red button to reset the unit successfully. Turn the gas supply on and check for leaks by spraying soap solution on the connections. I am gettin tempure sensor failure code (#5) what should I be replacing. Reasons Why There Is Water Leak Inside Refrigerator, Why Does My Air Conditioner Keep Freezing Up? Smith - Troubleshooting help - Hello my frist post here. The repair guide covers indoor, outdoor, condensing, non-condensing, and ultra-low NOx water heaters with on-demand technology. Smith Water Heater Parts. How To Fix: First off, turn the gas control knob to the off position. There could be an issue with the power supply of your water heater and thus it could be failing. Bathtub faucets typically have a flow rate of 5 Gallons per Minute. You also have the option to opt-out of these cookies. Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. Comprehensive information about your new appliance - from getting started to cleaning and maintenance - with answers to frequently asked questions. Hi, I have an AO Smith GCVL 40 300 natural gas with a Honeywell valve. Clean your AFR rod of any soot, and check for any damage or loose connections to see if you need to find a replacement. If the condensate drain is not properly installed on the vent collar of the water heater, then there could be water in the internal combustion engine. A water heater leaks from different places like from the top, bottom, and side. Is Spray Paint Flammable? And the reason is the thermistor gets shorted electrically. Install a new gas control valve and tighten it up using the 4 gas pipe by turning it clockwise. If there is a scale build up, then you should also check for any water leakages that are causing scale to build up inside your water heater. These cookies will be stored in your browser only with your consent. I would How do I reset my A.O. This website uses cookies to improve your experience while you navigate through the website. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. on: function(evt, cb) { Keep in mind that the error codes are shown differently if the units are connected through the Easy-Link System it can be seen what the error code is and which unit has it. Your AO Smith Electric Water Heater will throw the error codes E10, E11, E12, and E13 either for an open inlet temperature sensor or open thermistor. AO Smith ES12-50R55DV (50 gallon) electric hot water tank. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. And secondly, loose wiring connections can also cause this symptom. We use cookies to ensure that we give you the best experience on our website. So, its worth bookmarking this article. Adjust the valves on the main line to set the water pressure at the right level. The work of the stack flue sensor is to detect the exhaust temperature of the heater and make sure that it does not exceed 176 degrees Celsius. It usually means that there is a problem with the bypass valve. Follow the below steps to change the part correctly: Your AO Smith Water Heaters status light will blink 5 times every three seconds if the temperature sensor gets defective. FIX: Debris on the thermistor, loose or broken wire connection. Solution: Check the wire connection, wire breakage, and debris on the flow sensor impeller. To determine if the heating element is shorted out, plug in a multimeter and test if the element, itself, is shorted. Thirdly, locate the thermistor on your water heater. I am still getting the error code. It may not display this or other websites correctly. Products: Water Heaters . They also have to make sure that the flame rod does not come with soot. FIX: Is the water heater set for the right elevation? What should you do first is- turn the gas control valve to the off position. Solution: Is the water heater set for the right elevation? You can read this article on Rheem Water Heater Leaking. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. To solve this error, check the thermistor to see if there are any loose wires or breakages that are causing the failure. Error code 441 (LED flashes two times) Problem: Flow sensor. Many reasons cause your water heater to heat the water excessively. window.mc4wp = window.mc4wp || { Smith Water Heater Manuals Anthony Barnes July 23, 2018 Need to Hire a Plumber? We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Next, thread a 4 section of gas pipe into the inlet and use it to turn the gas control valve counter-clockwise to remove the gas control valve. FIX: Check for blockage in the vents, the distance between the intake and exhaust terminals are per instructions and remove if there is grease or dirt in the gas burner and fan motor. To fix the tankless water heater from AO Smith properly and fast, we will show all three error codes (in the subtitle), the first for the units with the remote controller, the second for the units with the 7-Seg LED, and third are those heaters that do not have the remote only blinking LED. CODE: 10 (101), Five times PROBLEM: Warning for the "991" error code. It may stay that way for a few hours but eventually the heater shuts off and the light flashes red (2 times) again. Already you know how to sort out the reasons behind the code and solve your Pentair heater error code E05. You are using an out of date browser. Copyright 2020 - 2022 | All rights reserved. I hav been reading some similar posts regarding this issue, and I think I have made the proper analysis. 7+ Common AO Smith Water Heater Troubleshooting Codes. AO Smith Water Heater Error Code E02 [5 Easy Fixes] 1. Higher temperatures increase the risk of scalding, but even at 120F, hot water can Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features. To bring your water heater to a normal operating state, you should replace the temperature sensor. If the sensor fails to properly detect the temperature or it exceeds the limit, then the E05 error code appears. CODE: 331, Two timesPROBLEM: Mixing thermistor failure. It will be convenient for the homeowners who are handyman at the same time. What I will break down on this in-depth guide on AO Smith Water Heater Troubleshooting Lights: It depends on how many times the flashing light is blinking. If yes, its because the pilot light got extinguished recently and the thermopile is cooling down. Products. It will clear the error code. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Water Heaters. The flame rod should be free from dirt and grease, and the computer board should not be damaged. var intYear = dteNow.getFullYear(); CODE: 341, Two timesPROBLEM: Exhaust thermistor failure. Than ks anyway Appliance Technician: Chester Just ignore the pop-up call request. How to tell if the AO smith water heater is working? However, there is no need to be panicked because they have the solution for this circumstance. Debris and dirt could also be affecting the thermistor, so clean anything away and try again. Tank. forms: { Problem: Miscommunication in an Easy-Link system. This error code indicates that there is a problem with the flow sensor on your AO smith tankless water heater. FIX: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. Check for hidden leaks in hot water system . } To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Smith Water Heater, look no further! Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Tankless Water Heater Stuck In Standby Mode [Solved! The solution for this problem is by checking the Hi-limit switch. CODE: 51, 55, 510, 551, Six timesPROBLEM: Abnormal gas solenoid valve. Find the most common problems and see how to fix issues. Our comprehensive A.O. Smith Water Heater Troubleshooting. It also causes the heater to shut down completely and display the E05 code on the Pentair heater. Now there are quite a few reasons why this error code appears, including a faulty stack flue sensor, damaged thermal regulator, and improper gas pressure. Shop by Popular AO Smith Water Heater Models. Solution: Check if there is a loose or breakage in the wire connection or debris on the thermistor. So, the corrective action you need to take is- check the thermopile and replace it if it gets defective. Next, check for water leaks and fix them if needed. If you're looking for help fixing your A.O. Turn the gas control valve to the off position in the first place. A Pentair pool heater typically functions for 6 to 12 years on average. FIX: Check is there a loose or breakage in wire connection or debris on the thermistor. No, it's not. Second, the thermopile of your gas water heater has not reached its operating temperature yet. Is the surrounding air contaminated? Learn about AO Smith tankless error codes for easy and inexpensive troubleshooting. I replaced it with another AO Smith model, but a more base model without the smart module option. In this case, you must flush the unit. Once you solve the leak issue, return the electric power to your water heater. Learn how to inspect and replace a water heater dip tube and solve the problems related to not enough hot water or sediment buildup. Related Repair Pages:A.O. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Once the thermopile reaches its operating temperature, the status light will no longer remain solid red. Our comprehensive A.O. Smith Water Heater error code guide will explain common issues, provide tips, and show you how to read your model's error codes. The solution for this problem is by checking the Hi-limit switch. To solve this problem, you will need to find the correct settings for your water heaters model and reset them on the computer board. AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. Next, check the heating element for damage. Spray it on the gas connections (you can also apply the mixture with the sponge or paintbrush). Understanding Noritz error codes and troubleshooting Noritz water heaters. CODE: 39, 391, Two timesPROBLEM: Problem with the air-fuel ratio rod - AFR. How To Fix: To fix this issue, you should replace the control board. On the other hand, your AO Smith Water Heater goes through problems if the status light flashes more than 1 times followed by a three-second pause. Leak Shield shut off valve automatically shuts off watersupply when a leak is detected (accessoryincluded). This error code is closely related to the error code 11 (111) as it is a sign that your water heater is losing its flame. If this doesnt bring any luck to you, the best bait is to call a professional for further assistance. This error code pops up whenever there is a fault with the fan motor of your tankless water heater. Gas water heater using too much gas. Find the right water heater for your needs. A.O. The thermostat(s) on this water heater have been factory set to 120F to reduce the risk of scald injury. Dont forget to use Teflon tape on the gas piping connections and fitting on the back of the gas valve that screws into the tank. Manage Settings I don't think I should have yo pay anyone. Solution: Check if the Hi-limit switch properly functions and that there is no loose or broken wire connections, no soot on the flame rod, or a damaged computer board. Just follow the step-by-step instructions I mentioned in the Status Light Flashing 4 Times section. FIX: Debris on the thermistor, loose or broken wire connection. I reset the breaker and it started up a few hours later. For example, a model 510 will display the numerical code on the 7-Seg LED on the computer board, while the 110 and 310 models only a blinking red LED that can flash one time or more. Then, leave the unit for 10 minutes to let the thermopile cool down. To fix this issue, you should replace this part. Smith water heater? This chapter will discuss everything you need to know about the flashing light codes on AO Smith Water Heater. This is exactly where the thermistor is located, depending on models: Once you locate the thermistor, detach the thermistor wires from the control board. The wires connected to the stack flue sensor of the Pentair pool heater often loosen up automatically or get damaged. e. AO Smith Water Heater will throw an error code or make a beeping noise if the unit is not working properly. As a result, you can figure out the issue quickly and take the necessary steps to fix the problem. What you need to do is- attach the thermistor wires to the control board. Now there are quite a few reasons why this error code appears, including a faulty stack flue sensor, damaged thermal regulator, and improper gas pressure. All rights reserved. This error should really be addressed by a technician, but you can also open up your water heater to check for any wire breakages or loose connections. COPYRIGHT 2023. You dont need to take any corrective actions as the status light of a functioning unit blinks 1 time every 3 seconds. Another sign that this is the issue is if the error code is blinking five times. Generally, the water gets too hot if the gas control valve/thermostat is at fault. CODE: 651, Four timesPROBLEM: Flow adjustment valve fault. Smith University | An Education in Hotwater Register NOW for live online workshops! Open up the control panel and check the wires connected to the stack flue sensor. Where this thermistor is will vary from model to model, so you will need to check your manual to find it on your water heater. To have the unit working properly, it has to be supplied with the power and correct connection. An example of data being processed may be a unique identifier stored in a cookie. Solution: Ensure the flow sensor wires are correctly connected and with no damage. Make sure that there are no parts of the sensor that require work. Leave a comment in the box below if you have any questions about the Pentair pool heater. Find the right water heater for your needs. Alternatively, you should check for any loose connections and damaged wires that could be behind this power loss. Clean away any dirt or debris and check the quality of the connection wires. Smith Water Heater Prices. Next, use the -inch open-end wrench and pull out the thermistor by turning it counter-clockwise. Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc. This final error code indicates that there is a false flame being detected within your water heater. I already discussed how to make the replacement. Error code E02 on AO Smith Electric Tankless Water Heater indicates that the unit determines the heated water exceeds the temperature limit. First off, relight the pilot following the steps I mentioned earlier to verify the status light is blinking 4 times. Solution: Check the wire connection, wire breakage, and debris on the flow sensor impeller. Should the water heater light be blinking? Solution: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with dust, burn marks on the computer board. To fix this issue, you should replace the control board. Remove the access panel and fold away the insulation. *Annual energy costs are estimated from the energy efficiency of each water heater, your households estimated water usage & set temperature, the average We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Remove the upper access panel by using a flathead screwdriver. This cookie is set by GDPR Cookie Consent plugin. Turn the valve back on and set the pressure to the proper temperature. FIX: Check for the proper settings on the computer board. Solution: Check if the condensate drain is installed on the vent collar of the heater. Just shut off the electric supply to the unit. CODE: 31, 311, Two timesPROBLEM: Outlet thermistor failure. Leak Watch Smart technologyimmediately alerts you of a leak for yourpeace of mind. All of the above error codes all point to the same problem: an issue with your gas solenoid valve. Once you have, make sure all the connections are secure and safe and clean away any dirt or debris that could be the issue. The showers in homes built after 1992 typically have a flow rate of 2.1 Gallons Per Minute. smith gas water heater installation user and service manual (102 pages) Water Heater A.O.Smith GPSX-50L Owner's Manual. This is usually caused by scale build up which locks the motor drive. Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Electric Water Heater Troubleshooting, AO Smith Water Heater Troubleshooting Codes, AO Smith Gas Water Heater Troubleshooting, 9 AO Smith Gas Water Heater Troubleshooting Tips, AO Smith Water Heater Not Heating [5 Easy Solutions], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide]. In the Pentair pool heater exchanger, the thermal regulator helps the water reach a certain temperature and heat up the pool water. No spam, we promise. Just connect a garden hose to the drain plug at the bottom of the unit and place the other end of the hose to the nearest floor drain. Your AO Smith Water Heater wont light up if there are electrical problems like the thermopile wires come loose. They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. Get a free estimate online from top local home service pros in your area. Search For Support Documentation For Your A. O. Smith Brand Water Heater. To solve & clear the error message, turn the power off to your water heater first. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! I Before doing so, don't forget to check the wiring attached to the control board. Jenn-Air JGS8750ADB Control Panel Burning Hot! document.write(intYear); All rights reservedDisclaimer:The content published on hotwatertalk.com is not professional advice. If you see any scale buildup on your motor drive, you will need to clean it away with hydrochloric acid and water mixture (wear appropriate protection gear while handling this mixture). Nevertheless, it will mean that people have to learn more about Ao Smith Water Heater Codes for understanding the error and the solution. If your AO Smith Electric Tankless Water Heater throws the error code E51 or E52, understand the user interface lost its connection with the control board. This error code is another thermistor failure but this time, it is referring to the mixing or mix thermistor. Smith Water Heaters, 500 Tennessee Waltz Parkway, Ashland City, TN 37015 USA, Tel: 1-800-433-2545 Website: www.aosmithwaterheaters.com Email: parts@hotwater.com A.O. This is A.O. Either the thermopile doesnt cool down quickly or the pilot valve is stuck in an open position. And this will reset the water heater successfully. Mix the soap and water in a spray bottle. Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. What does ECC code mean A.O. You may need to install Adobe Acrobat Reader to view these documents. Blue light now heartbeat dim & bright. var dteNow = new Date(); Solution: Debris on the thermistor, loose or broken wire connection. The initial setting is 120F, but you're in control after installation. If it doesnt throw a trouble code, make no beeping, or flashing light, and understand the water is functioning properly. As a result, you can now easily diagnose your water heater that will save you both time and money. Of course, there will be a solution which can be used for fixing this problem. Use the pipe wrench to tighten the fittings. If there is no scale build up, then you should check the connections and wires around the flow adjustment valve. This error code occurs when there is a problem with the inlet thermistor. There will be various considerations which should be made in this circumstance for finding the perfect one. As a result, the heating element stops warming the water. It is a 50 gallon A O Smith just installed in new home 6 months ago.LG12-50R55DV 210. Register now, spots are limited! Electronic User Interface allows you to easily set temperature, operating mode, and child safety lock feature. If they come loose, tighten them up. You can do a few basic checks first like making sure there are no loose wire connections or soot on the flame rod. ao smith water heater error code e05. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. Too High Temperature 2. I initially had to replace the lower element due to limescale. Replacing the gas control valve/thermostat will be a simple fix to this issue. Very simple. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. If it's shorted out, unplug the machine . More error codes can be found after all. I initially had to replace the lower element due to limescale. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. When the temperature of the stack flue rises above a certain degree, this error message will show up on your heater. This cookie is set by GDPR Cookie Consent plugin. There will be some great advantages found from this type of water heater, including the remote controller and self-diagnosing function. Regarding this, you need to replace the thermocouple or the wire connectors. CODE: 10 (101), Five timesPROBLEM: Warning for the "991" error code. This error code signifies that there is a problem with your outlet thermistor. CODE: 03 (031), One time PROBLEM: Incorrect dipswitch settings. Use the search box below to quickly find your model number. The water heater is surely essential to support modern households, and we can make sure that people will look for the best water heater which can be used for their household needs. Sometimes if you are lucky, it could just be a bit of soot blocking the sensors other times, you may need to find a replacement AFR rod as soon as possible. If you don't see the tankless water heater problem you're having here, or if you need technical support with your water heater, please visit our help desk to schedule an appointment, or call us at 866-356-1992. Get Help from a Local Plumber. For a better experience, please enable JavaScript in your browser before proceeding. This numerical code is telling you about the ignition failure. Find the right water treatment products for your needs. A.O. Fix the loose wiring and replace the damaged wires. Smith NG water heater Commercial Shut down. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. What Does Flashing Light Mean On Ao Smith Water Heater? Fold away the insulation to access the reset button (its red). Basically, both 2-chamber and 4-chamber models will pop up with those error codes. These cookies track visitors across websites and collect information to provide customized ads. Try our Product Selector Tool to find the right models for your needs-for both heating and treating your home's water. To solve this error, you will need to carry out the same checks and treatments in the above error. I turned off for 5 minutes then back on. } The cookie is used to store the user consent for the cookies in the category "Analytics". They also have to make sure that the flame rod does not come with soot. The Pentair heater e05 error code is one of the 12 error codes for this pool heater. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. An Easy Guide on How to Fix A Squeaky Door Without Taking It Apart, How to Remove A Broken Drill Bit from Wood? Otherwise, the status light wont blink. Ignition failure is not an uncommon issue with water heaters and boilers, but its also highly recommended that you solve this issue by calling a technician to your home.

Philadelphia Department Of Veterans Affairs, Articles A